- Description
- Reviews
Fire and Gas Advanced Training
This Course covers Basic introduction, working principles, testing and maintenance procedures for Fire and Gas detection Systems.
Who this course is for:
Instrumentation Engineer, technician, supervisor, Fire alarm technician, and experienced professionals.
Course Outline
- Basic Fire Alarm System
-
-
- Introduction of fire alarm panel, it’s working.
- Wiring & Loop diagram explained.
- Fire Alarm System testing procedure.
- Inspection and Testing of Fire Alarm System
- What are Detection Zones, Alarm Zones and Operation Zones
- Analysis of popular Alarm Systems such as the Autronica
- Description of the Autrosafe Interactive Fire Alarm System
- AutroSafe System Components
- Autrosafe loop units with Self Verify and DYFI+
- Addressing Principles
- AS2000
- Explanation of popular standards like EN 54-2 and EN 54-4
- Operator Panels, Repeater Panel, Information Panel and Controller
- Operating Fire Alarm Control Panel BS-310/320 or Operator Panel BS-330
-
- Smoke detector & its working.
-
-
- Smoke Detector maintenance & testing procedure.
-
- Heat detector & its working.
-
-
- Heat Detector maintenance & testing procedure.
-
- What MCP & its working.
-
-
- Typical application & actions.
- MCP testing procedure.
-
- Fire Suppression System working.
-
-
- Fire Suppression System Maintenance and testing Procedure.
-
- Fire & Gas detection system and its function.
-
-
- Types of signals, typical application and actions of sensors.
-
- System interfacing with HVAC, fire pumps and fire protection system.
- Deluge System introduction and working principle.
-
-
- Deluge System application.
- Deluge System operation.
- Deluge System inspection, testing & Maintenance Procedure.
-
- What is line monitoring.
-
-
- Why line monitoring is important.
-
- Flame Detector introduction & How it works.
-
-
- Types of Flame Detector.
- Flame Detector Maintenance & testing Procedure.
- Typical applications & actions.
-
- Point Gas Detector introduction & How it works.
-
-
- Why Point Gas Detector is used.
- Point Gas Detector Maintenance, testing and calibration Procedure.
- Typical applications & actions.
-
- Open Path Gas Detector introduction & their working principle.
-
-
- Open Path Gas Detector Maintenance Procedure.
- Typical applications & actions
-
Hands On Session
- Identify components installed on racks in a fire and gas panel.
- Identify testing equipment to activate fire and gas detectors.
- How to replace components in a fire and gas panel
- How to simulate activation of detectors using approved test equipment.
- How to dismantle, repair and replace defective fire and gas detectors
- How to override the shutdown activation facility before starting any function test using the correct methods and procedures
- Carry out Plant Calibration function check procedures on the following:
- Equipment, Smoke Detectors, Heat Detectors, IR and Video Flame Detectors, IR Gas Detectors, Toxic Gas
- Detectors, Deluge and Sprinkler Systems activated by PolyFlow tubing
- Fusible plug, frangible bulbs, Invensys Trident plc or any other PLC
Please, login to leave a review

Share
Popular courses